TOP Corporation’s Simple and Easy-to-Use Infusion Pump, developed for a New Standard.
More information about this product? Feel free to contact us.
TOP-2500 Infusion Pump
The TOP-2500 is a volume pump, used to administer medical fluids in a controlled and preset manner, for a broad variety of infusion therapies. It was developed as a New Standard: a very light and compact machine, with a clear focus on simplicity and safety. Preparation and use are very straightforward, following a well indicated series of successive top-to-bottom steps.
There are two modes of operation: a general mode, with use of any compatible infusion set, and the ‘H-Series’ mode, a more accurate and controlled proces with TOP’s dedicated infusion set.
The infusion set is guided along a slot with peristaltic fingers, through upstream and downstream occlusion sensors and an air detector sensor, safely secured behind the front door. A tube clamp prevents free flow of infusion fluid when the door is open. Bright key lights and a door light help to operate the TOP-2500 in the dark.
Safety
Events are indicated through sounds and multi-coloured lights. The internal battery ensures continued operation during power outages or transport, and may last for up until 4 hours when full.
Specifications
- Infusion Sets: Designated Infusion Sets TOP H-Series, General 20 drops/ml Infusion Sets, General 60 drops/ml Infusion Sets (various brands)
- Flow Rate Range Designated 20 drops/ml IV Set: 1 ~ 1.200 ml/h, Micro Mode: 0,1 ~ 99,9 ml/h
- Flow Rate Range Designated 60 drops/ml IV Set: 1 ~ 150 ml/h, Micro Mode: 0,1 ~ 99,9 ml/h
- Flow Rate Range General 20 drops/ml IV Set: 1 ~ 360 ml/h, Micro Mode: 1 ~ 120 drops/min.
- Flow Rate Range General 60 drops/ml IV Set: 1 ~ 150 ml/h, Micro Mode: 1 ~ 150 drops/min.
- Purge Flow Rate: Maximum flow in each flow rate range
- KVO Flow Rate: 0,1 – 5,00 ml/h
- Volume Limit Range: 0,1 – 9.999,9 ml (0,1 ml increments)
- Total Volume Range: 0,0 – 9.999,9 ml (0,1 ml increments
- Infusion Accuracy U-Series Mode: ±5% (IEC60601-2-24, Clinical situations)
- Infusion Accuracy General Mode: ±10% (IEC60601-2-24, Clinical situations, Water or Saline)
- Occlusion Detection Downstream H-Series: High 120±30 kPa, Medium 90±30 kPa, Low 60±30 kPa, Lowest 30±20 kPa
- Occlusion Detection Downstream General: High, Medium, Low, Lowest
- Air-in-Line Detection Sensitivity: High, Medium, Low
- Alarms: High Priority, Low Priority, Information Signals
- Dimensions and Weight: 180 x 113 x 202 mm, approx. 1,8 kg (including clamp and battery)
Special Functions Include
Automatic Infusion Set Attaching Function, Infusion Set Setting Function, Anti-Bolus Function, KVO (Keep Vein Open) Function, Standby, Auto Power Off, Repeat Alarm, Buzzer Setting, Power Supply Switch Notice, Key-Lock Function, Maintenance Timer, History Function, Alarm Setting Confirmation Function